A cyclotron is a device that uses magnetic and electric fields together to make charged particles move in a cyclotron motion, in which they are repeatedly accelerated by a high-frequency electric field. It is an important instrument in high-energy physics.
Raysov inductive electron cyclotron has a high cost performance, the purchase cost is 50-65% of the same level (4 MeV. linear gas pedal, post maintenance cost is 10-20%. The equipment is small and light, 1/4 of the linear gas pedal, and the radiator weighs only 100 kg, which is convenient for placement, illumination of larger workpieces, and flexible movement. Because the linear gas pedal does not need the configuration of the carriage and yoke, although the thickness of the protective wall and linear gas pedal is basically equal (1.5m.), the height of the protective room, the area can be greatly reduced, the construction cost of the protective room for the linear gas pedal 50%. The modulator part is air-cooled instead of water-cooled, which reduces the failure link and is less affected by the environment.
Therefore, the inductive electron cyclotron is widely used in the casting and welding of large workpieces, bridges, concrete testing and other fields of nondestructive testing.
Six Features
01 Lifetime use!
02 7MeV (the original 7.5MeV latest improved type)
03High energy, small dose in line with environmental requirements
04 can be used with high-energy plate detector digital imaging, flexible use
05 good reliability, stable operation, can be used for long-term stable work
06 low maintenance costs, only need to regularly replace the accelerator tube, the cost is greatly reduced compared to linear gas pedal.
Technical specifications - 7MeV inductive electron cyclotron
Inductive electron cyclotron-radiator
Inductive Electron Cyclotron-Controller
1. Electron beam energy: 7 MeV energy 3.0-7 MeV adjustable.
2. achievable phase quality sensitivity: at least in the thickness of 50 ~ 200mm (A3 steel) detection range, photographic sensitivity of 1-2T (ASTM hole type image quality meter or 1% line type image quality meter)
3. dose rate: ≥ 10cGy / min (ray center axis from the target at 1m)
4 focus size: ≤ 0.3X2mm
5. irradiation field of view: the central beam of rays and the side beam angle ≤ 15 °
6 ray uniformity: X-ray uniformity > 60% (in deviation from the X-ray central axis ± 7.5 ° at the dose rate and 0 ° direction on the central axis of the dose rate percentage.
7. dose stability and dose stabilization time required: dose stability ≤ 2%, dose stabilization time required ≤ 10s.
8. Continuous working time: not less than 10 hours per day and night. In the case of fan on, work 45 minutes, rest 15 minutes.
9. Maximum power: 3.5kW
10. working conditions: ambient temperature: 0-50 ℃ relative humidity: 85
Exposure curveScope of delivery:
Radiator (with bracket) 760×450×400mm 125kg
Power supply box 550×370×460mm 35kg
Controller 130×200×35mm 2.2kg
Radiation safety warning part Ф130×80mm 1.5kg
Control cable 25m
Emitter cable 5m
Alarm light cable 25m